Strategic Approaches of Controlling Variables in RP-HPLC Method Development and Validation: A Review
Downloads
High Performance Liquid chromatography is the principal technique in accessing the drug, its various impurities and drug related degradants that can form on synthesis or storage in pharmaceutical products. It results in highly efficient separations and in most cases provides high detection sensitivity. Most of the drugs in multi component dosage forms can be analyzed by HPLC method because of the several advantages like rapidity, specificity, accuracy, precision and ease of automation. Separation of components in a mixture is based on their interaction between a stationary and a mobile phase based on the properties such as polarity, electric charge (for ionic compounds), pH, functional groups and size of the molecule. Before starting method development there should be good understanding of the chemical structure, polarity. pH, pKa, molecular spectral absorbance electric charges(ionic compounds) of the molecule. HPLC methods development and validation play important roles in new discovery, development, manufacture of pharmaceutical drugs and various other studies related to humans and animals.
KK Unger, Porus silica, Journal of Chromatographic Library, Elsevier publishingvolume 16(1979)187-219
W. R. Melander and C. Horvath, in High-Performance Liquid Chromatography: Advances and Perspectives, Vol. 2, C. Horvath, ed., Academic Press, San Diego, CA, (1980) 113.
. J. A. Lewis, D. C. Lommen, W. D. Raddatz, 1. W. Dolan, and L. R. Snyder, J. Chromatogr.,592 (1992) 183.
P. J. Shoenmakers and R. Tijssen, J. Chromatogr. A, 656 (1993) 577.
R. F. Doerge, ed., Wilson and Giswald’s Textbook of Organic Medicinal and Pharmaceutical Chemistry, J.B. Lippincott,
Philadelphia, PA1982, Appendix B
pKalc Expert system, CompuDrug Chemistry, Inc., Budapest, Hungary, 1992
L. R. Snyder, J. J. Kirkland, J L. Glajch, Practical HPLC Method Development, John Wiley publication 2nd ed(1988) 3-19
CRC Handbook of Chemistry and Physics, CRC Press, 85th ed.( 2005) 2-38
J W Dolan. Journal of Chromatography A.; 965(2002) 195-205.
L. R. Snyder, J. J. Kirkland, J L. Glajch, Practical HPLC Method Development, John Wiley publication 2nd ed. (1988) 227-
C Kaushal, B Srivastava, A Process of Method Development: A Chromatographic Approach. J Chem Pharm Res,
(2)(2010)519-545.
P. J. Schoenmakers,Optimization of chromatographic selectivity, Journal of Chromatographic Library, volume 35(1986) 276-
FDA Guidance for Industry-Analytical Procedures and Method Validation, Chemistry, Manufacturing, and Controls
Documentation, Center for Drug Evaluation and Research (CDER) and Center for Biologics Evaluation and Research
(CBER), 2000.
Korany MA, Mahgoub H, Ossama TF, Hadir MM. Application of artifcial neural networks for response surface modelling in
HPLC method development. J Adv Res, 3(2012) 53-63
T. D. Wilson and D. M. Simmons, Chromatographia, 35 (1993) 295.
http://www.waters.com/watersdivision/pdf/Ic3AC.pdf.
J. J. Kirkland, M. A. van Straten, and H. A. Claessens, J. Chromatogr. A. 691 (1995) 3.
J. J. Kirkland, J. W. Henderson, J. Chromatogr. Sci., 32 (1994) 473.
J. PavelAnalyticaChimicaActa692 (2011) 1–25
L. R., Snyder, , J. J., Kirkland,, J. W. Dolan (2011). Introduction to modern liquid chromatography. Wiley interscience
publication, New York., 2nd ed. (1979)168 -234
L. R. Snyder and L.L.Kirkla ND, Introduction to Modern Liquid Chromatography, Wiley-Interscience, Newyork2nd ed. (
390-393
W. Hancock, R. Co Chloupek, J. J. Kirkland, and L. R. Snyder, J. Chromatagr;,686 (1994) 31.
CRC Handbook of Chemistry and Physics, 85th edn.; CRC Press, LLC: Boca Raton, FL, 2004–2005.
M. Roses, X. Subirats, E. Bosch, Journal of Chromatography A, 1216 (2009) 1756–1775
M.C. McMaster, HPLC A Practical User’s Guide, VCH Publishers, Inc.: New York( 1994) 85.
C.F. Poole, and , S.K. Poole, Chromatography Today, Elsevier Science: Amsterdam, The Netherlands(1991) 431
D.V. McCalley, J. Chromatogr. A 1994, 664, 139–147
R.A. Henry, D Gahagan, Design of Volatile Buffer Systems for LC Applications, (Keystone Scientific, Inc. Bellefonte, PA)
J. E. Hardcastle, I. Jano, Journal of Chromatography B, 717 (1998) 39–56
S. Espinosa, E. Bosch, M. Roses, Retention of Ionizable Compounds on HPLC Anal. Chem. 74(2002)3809-3818
U.D. Neue, “Separations Solutions: Mobile Phase pH American Laboratory, March (1999) 60
/preparing-a-buffer-solution-with-a-specific-ph-474-7261/
D.M., Bliesner Validating Chromatographic Methods, john wliey& sons, Inc.(2006) 88-92.
Validation of Analytical Procedures: Text and Methodology, International Conferences on Harmonization, Draft Revised
(2005), Q2 (R1).
N.Toomula, A. Kumar, S.D.Kumar, V.S. Bheemidi, Development and Validation of Analytical Methods for Pharmaceuticals,
J Anal Bioanal Techniques. 2(5) (2011) 1-4.
RA Journal of Applied Research
||Volume||2||Issue||11||Pages-733-750||Nov-2016|| ISSN (e): 2394-6709
www.rajournals.in
IC Value: 74.25 (Index Copernicus 2015/16)
Soni Love K, RAJAR Volume 2 Issue 11 NOV 2016 750
Validation of CompendialProcedures, United State Pharmacopeia, USP 36 NF, 27 (2) (2010).
T. Bhagyasree, N. Injeti, A. Azhakesan, U.M.V. Rao, A review on analytical method development and validation,International Journal of Pharmaceutical Research & Analysis, Vol 4 (8) (2014) 444-448.
W. A Brown, PR, HPLC and CE Principles and Practise, Academic press, California, 1997.
V. Kumar, R. Bharadwaj, G.G., S. Kumar, An Overview on HPLC Method Development, Optimization and Validation process for drug analysis, The Pharmaceutical and Chemical Journal, 2(2) (2015) 30-40
All Content should be original and unpublished.